Test Point 8
Test point 8
Motor of central valve
Signal implausible
Fault code 27
Diagnosis conditions
No control module fault stored.
No fault with supply voltage (5 volts).
Signal implausible
1. Check central valve for smooth operation.
2. Unplug connectors A, B, C and D from the heating/air-conditioning control.
3. Unplug connector from central valve drive motor.
4. Connect ohmmeter to connector A 12 and drive motor connector pin 1.
Display: [<] 5 ohms
Connect ohmmeter to connector B 9 and drive motor connector pin 2.
Display: [<] 5 ohms
Connect ohmmeter to connector C 8 and drive motor connector pin 3.
Display: [<] 5 ohms
Connect ohmmeter to connector D 4 and drive motor connector pin 4.
Display: [<] 5 ohms
Connect ohmmeter to connector D 12 and drive motor connector pin 5.
Display: [<] 5 ohms
5. Check wire from connector A 12 to drive motor pin 1 for short to B+.
6. Check wire from connector B 9 to drive motor pin 2 for short to B+ and short to ground.
7. Check wire from connector C 8 to drive motor pin 3 for short to B+ and short to ground.
8. Check wire from connector D 4 to drive motor pin 4 for short to B+ and short to ground.
9. Check wire from connector D 12 to drive motor pin 5 for short to B+ and short to ground.