Test Point 6
TEST POINT 6
Door Lock Barrel Open/Closed, Short To Ground
Fault Code 06
Fault Effect: No central locking or unlocking possible
Procedure
1. Pull plug I off the alarm system control module.
2. Disconnect plug connection X 11 (driver's side).
3. Disconnect plug connection X 12 (passenger's side).
4. Check the wires from the alarm system control module plug I, pin 35 to the door locks for short to ground.
Ohmmeter at alarm system control module plug I, pin 35 and ground
Display: infinity
5. Check driver's side door lock switch contact.
Ohmmeter at plug connection X 11, pin A2 (sleeve side) and ground.
- Door lock not actuated.
Display: infinity
- Door lock actuated towards "Closed".
Display: < 5 ohms
6. Check passenger's side door lock switch contact.
Ohmmeter at plug connection X 12, pin A2 (sleeve side) and ground.
- Door lock not actuated.
Display: infinity
- Door lock actuated towards "Closed".
Display: < 5 ohms
7. Check the wires from the alarm system control module plug I pin 15 to the door locks for short to ground.
Ohmmeter at alarm system control module plug I, pin 15 and ground.
Display: infinity
8. Check driver's side door lock switch contact.
Ohmmeter at plug connection X 11, pin A6 (sleeve side) and ground.
- Door lock not actuated.
Display: infinity
- Door lock actuated towards Open".
Display: < 5 ohms
9. Check passenger's side door lock switch contact.
Ohmmeter at plug connection X 12, pin A6 (sleeve side) and ground.
- Door lock not actuated.
Display: infinity
- Door lock actuated towards "Open".
Display: < 5 ohms