Test Point 12
TEST POINT 12
Hall-effect Sensor Height Adjustment, Open Circuit
Fault Code 12
This fault is stored in the following cases:
1. There is an open circuit in the wire to the Hall-effect sensor fore-and-aft adjustment.
2. The Hall-effect sensor is faulty.
3. The control module is faulty.
Fault Effect: No automatic adjustment possible, manual only 500 ms
Elimination:
- Check plug on control module for contact and damage. Check wire to sensor for damage.
- Once the cause of the fault has been found and eliminated, actuate the height adjustment switch. The text in the fault memory changes from present to not present if the cause of the fault has really been eliminated.
- If no fault is detected in the wire on the sensor, replace the electric motor for height adjustment.
- If the fault is still present, replace control module.