Oxygen Sensing Error By Means of Short Test, Bank 2 - Below Limit
P1134
419 Oxygen Sensing Error by means of Short Test, Bank 2 - Below Limit
Diagnosis conditions
- Mixture adaptation performed with the Porsche System Tester 2
Possible fault cause
- Incorrect signal from MAF sensor
- Fuel pressure too high
- Fuel injector leaking
- EVAP canister purge valve open
Diagnosis/troubleshooting