Removing and Installing Fusible Element In the Current Distributor
Removing And Installing Fusible Element In The Current Distributor
Removing Fusible Element From The Current Distributor
DANGER:
Danger of injury and risk of damage.
- The battery must be clamped off before starting the assembly work.
1. Remove cover for current distributor and remove the service label.
2. Carefully lever off the cover -A-, e.g. with a screwdriver -arrow-. This will break the locking tabs and the cover can be removed.
3. Remove broken locking tabs from the current distributor.
4. Unscrew the two hexagon nuts M 5 -3- from the blown fusible element -1- and remove with the washers -2-.
Installing Fusible Element In The Current Distributor
NOTE:
The following spare parts must be replaced.
- Hexagon nut M 8, 1 piece
- Repair kit - replacement fusible element
1. Insert new fusible element -1-, using new washers -2- and new hexagon nuts -3- M 5. Tightening torque: 4.0 Nm (3.0 ftlb.)
2. Position and engage the blue after-sales service cover -A-.
3. Close the current distributor cover until it engages -arrow-.
4. Affix the blue service label.