Mechanical Specifications
NOTE:
- When installing the refrigerant lines, the screw connections and the O-rings must be wetted with refrigerant oil.
- The refrigerant oil must be disposed of as special-category waste.
Technical Data For The Air-Conditioning System
Compressor type 7 SB 16
Refrigerant quantity 900 g
Refrigerant type R134a
Refrigerant oil capacity (compressor) 195 ± 15 cc
Refrigerant oil type ND 8 PAG
Torque Specs
Hex-head bolts on:
Expansion valve
M6 9 Nm (6.5 ft.lbs)
M5 6 Nm (4.5 ft.lbs)
Compressor
M8 23 Nm (17 ft.lbs)
Refrigerant line
M8 23 Nm (17 ft.lbs)
Oil filler plug
M10 26 - 36 Nm (19 - 27 ft.lbs)
Fluid tank
M6 6 Nm (4.5 ft.lbs)
Flange connections on refrigerant lines
M8 14 Nm (10 ft.lbs)