Fault Code 2
Fault code 2
Motor circuit, right
This fault is stored in the following cases:
1. Short circuit to ground or open circuit in the circuit between control module and servomotor for HBA, right, terminals 5, 6, 7, 8
2. Servomotor for HBA, right, is faulty
3. The control module is faulty
Elimination:
- Switch off ignition
- Pull plug off the control module
- Pull plug off the servomotor for HBA
- Check for open circuit in the supply leads to the servomotor for HBA, right, terminals 5, 6, 7, 8
Ohmmeter display < 5 Ohm
- Check for short to B+ in the supply leads to the servomotor for HBA
- Ohmmeter connected to terminals 5, 6, 7, and 8; measure resistance to ground
Ohmmeter display Infinity Ohm
- Check for short circuits between the leads.
- If no fault is detected in the wires, replace the servomotor for HBA.