Fault Code 29
Fault Code 29
Outside Air/Recirculation Air Flap Motor - No Reaction To Activation, Signal Implausible
Diagnostic conditions
- Ignition on
- No control unit fault stored
- No sensor supply voltage fault stored (5 V)
Possible cause of fault
- Short circuit to B+/ground/between wires or open circuit in wiring between air-conditioning system regulator and outside air/recirculation air flap
- Outside air/recirculation air flap stiff
- Outside air/recirculation air flap drive motor faulty
- Air-conditioning system regulator faulty
Affected pins
Plug B, pins 4, 9 and 20
Plug D, pins 5 and 13
Diagnosis/troubleshooting