P0028
P0028
Valve lift control, bank 2 output stage - open circuit
Diagnosis conditions
- Engine running
Possible fault cause
- Open circuit in triggering wire
- Open circuit in B+ supply
- Solenoid hydraulic valve faulty
Affected terminals
III/26
Diagnosis/troubleshooting
NOTE: The wiring for the solenoid hydraulic valve is routed via the connector X 59/1 pin 11
Valve lift control, bank 2, output stage - below limit
Diagnosis conditions
- Engine running
Possible fault cause
- Triggering wire short to ground
- Solenoid hydraulic valve faulty
Affected terminals
III/26
Diagnosis/troubleshooting
NOTE: The wiring for the solenoid hydraulic valve is routed via the connector X 59/1 pin 11
Valve lift control, bank 2, output stage - above limit
Diagnosis conditions
- Engine running
Possible fault cause
- Triggering wire short to B+
Affected terminals
III/26
Diagnosis/troubleshooting
NOTE: The wiring for the solenoid hydraulic valve is routed via the connector X 59/1 pin 11