P1328
P1328
Inlet camshaft output stage - open circuit
Diagnosis conditions
- Engine running
Possible fault cause
- Open circuit in triggering wire
- Open circuit in B+ supply
- Solenoid hydraulic valve faulty
Affected terminals
V/7
Diagnosis/troubleshooting
NOTE: The wiring for the solenoid hydraulic valve is routed via the connector X 59/1 pin 14