Test Point 6
Fault, Fault Code 25 Test Point 6
Supply voltage (5 volts)
Voltage too high Voltage too low Fault code 25
Possible causes, elimination, notes
Diagnosis conditions
No control module fault stored.
Voltage too high
1. Unplug connector C from the heating/air-conditioning control.
2. Connect voltmeter to C 8 and ground.
Switch on ignition.
Display: 0 volts
If the battery voltage is displayed, check the wiring harness for pinching and chafing damage.
3. Push on connector C.
4. Connect voltmeter to C 8 and ground.
Switch on ignition.
Display: 5 ± 0.5 volts
If more than 5.5 volts are displayed, replace the heating/air-conditioning control.
Voltage too low
1. Unplug connector C from the heating/air-conditioning control.
2. Unplug all connectors from the valve drive motors.
3. Connect ohmmeter to connector C 8 and ground.
Display: Infinite Ohms.
If 0 - 5 Ohms is displayed, check wiring harness for pinching and chafing damage.
4. Check potentiometer in the drive motors.
Temperature mixing valve:
Connect ohmmeter to pins 1 and 3.
Display: 4 - 5 kOhms at 23 degrees C
Footwell / defrost valve:
Connect ohmmeter to pins 1 and 3.
Display: 4 - 5 kOhms at 23 degrees C
Central valve:
Connect ohmmeter to pins 1 and 3.
Display: 4 - 5 kOhms at 23 degrees C
Outside air / recirculation valve:
Connect ohmmeter to pins 4 and 5.
Display: 4 - 5 kOhms at 23 degrees C