P2270
P2270
Oxygen sensor signal behind catalytic converter, too lean
Diagnostic conditions
- Mass air flow throughput 25 kg/h ... 120 kg/h
- Oxygen sensing behind catalytic converter active
- Basic adaptation stabilized
- No secondary air system diagnosis
- No tank ventilation diagnosis
- No high loading of carbon filter
- No other oxygen-sensor faults
Possible fault causes
- Oxygen sensor faulty (dynamically inert)