Calibrating Convertible Top
Calibrating Convertible Top
Preliminary work
Preliminary work for calibration
1. The convertible-top compartment lid drive must be repaired (after an emergency operation).
2. The valve screw of the hydraulic pump must be closed.
3. The engine compartment lid must be closed.
4. The upper microswitches of the left and right rear side section flaps are actuated when the opened convertible top is set down. See under Input signals in the Tester: Side flap top left or side flap top right. Read out fault memory if necessary and proceed according to the guided troubleshooting.
5. The lower microswitches of the left and right rear side section flaps are actuated when the convertible top is closed. See under Input signals in the Tester: Side flap bottom left or side flap bottom right. Read out fault memory if necessary and proceed according to the guided troubleshooting.
6. The convertible top compartment lid microswitch must be unlocked when the convertible top compartment lid is open. See under Input signals in the Tester: Convertible-top compartment lid released. The microswitch must be locked when the convertible top compartment lid is closed. See under Input signals in the Tester: Convertible-top compartment lid locked. Read out fault memory if necessary and proceed according to the guided troubleshooting.
General warning notes
Warning note on calibration
WARNING: Danger of injury and damage to property.
- Danger of injury when working on the convertible top
- No tools or other items should be stored within the movement range of the convertible top.
- The movement range of the convertible top and side window must be kept clear.
Calibrating convertible top
Calibration of the Cabriolet convertible top and the convertible top compartment lid is carried out via the diagnosis interface in the car and the PIWIS Tester. The respective potentiometer values (convertible top and convertible top compartment lid) are established during calibration. If the potentiometer values are plausible, the values are stored. The calibration values can then be calculated as a percentage by the convertible top control module from the potentiometer values.
1. Connect the Porsche System Tester to the diagnostic socket.
2. Switch on ignition.
3. Select the Convertible top menu item, Drive links, and select theCalibrate menu item in the command line which then appears.
4. Start calibration with the F8 key. Calibration can be started irrespective of whether the convertible top position is open or closed. The latching hook in roof frame 1 does not close during calibration.
The latching hook in roof frame 1 does not close during calibration.
Calibration is not counted as actuation. Calibration can be interrupted at any time with the F8 key on the Tester.