Heating and Air Conditioning: Testing and Inspection
Checking Air Conditioning
Tools
Troubleshooting the air conditioning system following complaints about cooling output
INFORMATION:
- The troubleshooting steps shown must be used if complaints are received about the cooling output of the air conditioning system.
- If it is not possible to clearly detect a leak using a leak detector, then only the leak detector additive supplied by SPEKTRONICS may be used. Leak detector additive: Traser line TP 3860 in dissolved form.
- This leak detector additive is available from service equipment providers (e.g. Waeco).
- For filling this Traser additive, special adapter kits are required, which are also available from service equipment providers (e.g. Waeco).
- Information on how to use the air-conditioning system and the procedure for filling it can be found in the operating instructions for the adapter kits.
Troubleshooting the air conditioning system following complaints about noises
INFORMATION:
- The troubleshooting steps shown must be used if complaints are received about noises in the air conditioning system.
- If it is not possible to clearly detect a leak using a leak detector, then only the leak detector additive supplied by SPEKTRONICS may be used. Leak detector additive: Traser line TP 3860 in dissolved form.
- This leak detector additive is available from service equipment providers (e.g. Waeco).
- For filling this Traser additive, special adapter kits are required, which are also available from service equipment providers (e.g. Waeco).
- Information on how to use the air-conditioning system and the procedure for filling it can be found in the operating instructions for the adapter kits.