Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Miscellaneous



Miscellaneous

The exact requirements to enter closed fuel control after engine start for the non continuous lambda sensor (HEGO) are:
- forced closed loop control if the ECT sensor is not working in accordance with the time requirements listed in paragraph 1968.2 (e) (10.2.2) (B) (ii) a and calculated temperature of temperature model above applicable value.
- lambda-probe operability (no actual errors stored for oxygen sensor) for continuous lambda control:

The following parameters / enable conditions are necessary to maintain closed loop fuel control:
- Oxygen probe operability (no actual errors stored for oxygen sensor)
- load is inside of two characteristic lines (min/ max)
- deceleration fuel cut off
- no error detected for:
a. injection valve power stage
b. misfire
c. secondary air system power stage