Operation CHARM: Car repair manuals for everyone.

P0153

P0153

Diagnosis information - DME (DFI)

Oxygen sensor ahead of cat. converter, bank 2, dynamic response

Diagnostic conditions
- Engine running more than 2 minutes
- Engine speed 1,184 ... 3,200 rpm
- Mass air flow 165 ... 600 mg/Stroke
- All 4 oxygen sensors ready for operation
- No overrun fuel shutoff

Possible fault causes
- Oxygen sensor ahead of catalytic converter, bank 2 faulty (old)