Operation CHARM: Car repair manuals for everyone.

Setpoint Definitions

P172F

Setpoint definitions

NOTE: The specified values and value ranges correspond to the OK state in each case.

Line test setpoints

Short circuit to B+:
- Setpoint voltage -0.5 V --> +0.5 V

Short circuit to ground:
- Setpoint resistance > 0.9 MOhm

Open circuit:
- Setpoint resistance < 2 Ohm

NOTE: The specified values apply only at an ambient temperature of approx. 20 °C (68 °F) (room temperature).

Temperature sensor setpoints

Temperature [°C] Resistance [Ohm]
0 > 800 --> < 820
4 > 830 --> < 850
25 > 980 --> < 1000
37 > 1070 --> < 1090