Operation CHARM: Car repair manuals for everyone.

Pressure Regulator 6 (Synchro Selection Gear: 4, 2, 1, 7), Short Circuit To Ground

P17AE

Diagnosis information - PDK

Pressure regulator 6 (synchro selection gear: 4, 2, 1, 7), short circuit to ground

Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are then tested and any faults are stored.

- Ignition on
- The following fault is not detected: P1832
- The following fault is not detected: P183A

Possible fault causes
- Line between pressure regulator 6 and PDK control unit, short circuit to ground
- Pressure regulator 6 faulty
- PDK control unit faulty

Fault setting conditions
- Internal current measurement, actuator solenoid R/P: current consumption = 0 mA
- Pressure regulator 6, internally measured control current = 0 mA
- Pressure regulator 6, measured voltage = 0 V

Fault effects
- Power supply switch-off for pressure regulators 4 to 6
- Power supply switch-off for solenoid valves 1 and 2
- Pressure regulator 4 switch-off
- Pressure regulator 5 switch-off
- Pressure regulator 6 switch-off
- Solenoid valve 1 switch-off
- Solenoid valve 2 switch-off
- Engaged gear is held until vehicle stops.
- Moving off possible in all gears
- Transmission limp-home indication in instrument cluster control unit