Ignition System Monitoring
12.1.13. IGNITION SYSTEM MONITORINGIgnition Coil Monitoring : Open line and Short circuit to ground
Description:
The purpose of this diagnostic is to check the integrity of the connection line in between ECU and coil (Open line, SCG).
Monitoring Function
The diagnosis is made with an integrated circuit which detects a failure in the command line of the ignition coils.
The following malfunctions are detected:
- Short circuit to ground
- Open load
Flow Chart: Ignition Diagnosis OL - SCG
Ignition Coil Monitoring : Short circuit to battery
Description:
The purpose of this diagnostic is to check the integrity of the connection line in between ECU and coil. (Short Circuit to battery)
Monitoring Function
The diagnosis is made with an integrated circuit which detects a failure in the command line of the ignition coils.
The following malfunctions are detected:
- Short circuit to battery
Flow Chart: Ignition Diagnosis - SCB
Ignition Coil Monitoring : Soft shutdown detection
Description:
The purpose of this diagnostic is to detect that coil has been cut-off without producing spark.
Monitoring Function
The diagnosis is made by an analogue acquisition of current feedback of the coil. If this current feedback is below than a calibratable threshold, soft shutdown is detected.
The following malfunctions are detected:
- Soft shutdown of ignition coil
Flow Chart: Ignition Diagnosis - SSDN