P0AA5
P0AA500Diagnosis information - High-voltage battery control unit
Contactor / Pre-charging contactor
DANGER
High voltage.
Death or severe injuries due to high voltage or high current.
- De-energise the vehicle in accordance with the guidelines.
- Work must not be performed on parts carrying a high voltage.
--> Please observe the following document in the PIWIS information system:
- 2X00IN Activation/commissioning of the High-voltage vehicle network
Diagnostic conditions
The control unit must be active in order to test internal function sequences and diagnosable inputs/outputs.
In the event of a fault, check whether the fault is permanently >present<. To perform the check, erase the fault memory, meet the diagnostic conditions and read out the fault memory again.
- Ignition on
Possible fault causes
- does not close
- does not open
Fault effects
- Function not available or available only to a limited extent