Pressure Regulator 7 (Hang-on Clutch), Short Circuit To B+
P17A7Diagnostic information - PDK
Pressure regulator 7 (hang-on clutch), short circuit to B+
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1832
- The following fault is not detected: P183A
- The following fault is not detected: P1842
Possible fault causes
- Line between pressure regulator 7 and PDK control unit, short circuit to B+
- Pressure regulator 7 faulty
- PDK control unit faulty
Fault setting conditions
- Internal current measurement, pressure regulator 7: current consumption > 850 mA
Fault effects
- Pressure regulator 7 switch-off
- Engaged gear is held until vehicle stops
- Transmission limp-home indication in instrument cluster control unit