Air Flow Meter/Sensor: Testing and Inspection
Fig. 7 Airflow meter electrical connector:
1.
Disconnect electrical connector,
Fig. 7, at airflow meter.
2.
Connect ohmmeter between connector terminals 7 and 8, then between 6 and 9.
3.
Resistance at each pair of terminals should be 0.5 ± .02 ohms.