Air Temperature Sensor ( Ambient / Intake )
Resistance/Temperature | Voltage/Temperature |
20-30 at -30 Kilo Ohms At Degrees Celsius (K ohms @ deg C) | approx. 4.5 at -30 Volts At Degrees Celsius (V @ deg C) Note: Power supply 5 V through a 2.74 k Ohm resister in the control module. |
7.0-11.4 at -10 Kilo Ohms At Degrees Celsius (K ohms @ deg C) | approx. 3.9 at -10 Volts At Degrees Celsius (V @ deg C) Note: Power supply 5 V through a 2.74 k Ohm resister in the control module. |
2.1-2.9 at 20 Kilo Ohms At Degrees Celsius (K ohms @ deg C) | approx. 2.4 at 20 Volts At Degrees Celsius (V @ deg C) Note: Power supply 5 V through a 2.74 k Ohm resister in the control module. |
1.0-1.3 at 40 Kilo Ohms At Degrees Celsius (K ohms @ deg C) | approx. 1.5 at 40 Volts At Degrees Celsius (V @ deg C) Note: Power supply 5 V through a 2.74 k Ohm resister in the control module. |
0.565-0.670 at 60 Kilo Ohms At Degrees Celsius (K ohms @ deg C) | approx. 0.9 at 60 Volts At Degrees Celsius (V @ deg C) Note: Power supply 5 V through a 2.74 k Ohm resister in the control module. |
0.295-0.365 at 80 Kilo Ohms At Degrees Celsius (K ohms @ deg C) | approx 0.54 at 80 Volts At Degrees Celsius (V @ deg C) Note: Power supply 5 V through a 2.74 k Ohm resister in the control module. |
0.24-0.26 at 90 Kilo Ohms At Degrees Celsius (K ohms @ deg C) | approx 0.41 at 90 Volts At Degrees Celsius (V @ deg C) Note: Power supply 5 V through a 2.74 k Ohm resister in the control module. |