Do you have access to Mitchell1 Prodemand? If you are willing to share user/password (we can pay $250), please get in contact with us ASAP: email operation-charm [[at]] tuta.io or click to submit anonymously
General System Condition - Refrigerant/Oil Overcharge
General System Condition Refrigerant/Oil Overcharge - L61:
KEY: HIGH PRESSURE SWITCH CYCLES COMPRESSOR ON AND OFF AT HIGH AMBIENT AIR TEMPERATURES.
THEN: System may be operating in an overcharged condition.
^ An overcharged condition will generate a poor and/or intermittent cooling complaint at higher ambient air temperatures. Intermittent complaints are caused by the pressure switch cycling the compressor On and Off.
^ Reclaim system using an approved recovery system, evacuate and recharge with 0.95 kg (2.09 lbs.) of R134a refrigerant.
^ Run another performance test.
^ An oil overcharge can occur if a compressor change is made without proper oil balancing. Review vehicle service history for compressor service.