Operation CHARM: Car repair manuals for everyone.
Do you have access to Mitchell1 Prodemand? If you are willing to share user/password (we can pay $250), please get in contact with us ASAP: email operation-charm [[at]] tuta.io or click to submit anonymously. (I know, we said we wouldn't ask any more...but it's important!)

Service Port HVAC: Service and Repair

SERVICE PORT VALVE CORE REPLACEMENT

TOOLS REQUIRED
- J 39400-A Halogen Leak Detector
- J 46246Valve Core Removal Tool

REMOVAL PROCEDURE
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.




2. Remove the service port valve core using J 46246 or equivalent.

INSTALLATION PROCEDURE




1. Install the service port valve core using J 46246 or equivalent.

NOTE: Refer to Fastener Notice in Service Precautions.

Tighten
Tighten the service port valve core to 2.5 N.m (22 lb in).

2. Evacuate and charge the refrigerant system. Refer to Refrigerant Recovery and Recharging.
3. Leak test the fittings using the J 39400-A.