Refrigerant Pressure Sensor / Switch: Service and Repair
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
Important: Refrigerant recovery is not required.
1. Remove the refrigerant pressure sensor wire harness connector.
2. Remove the refrigerant pressure sensor.
3. Remove and discard the O-ring.
Installation Procedure
1. Install a new O-ring.
Notice: Refer to Fastener Notice.
2. Install the refrigerant pressure sensor.
Tighten to 5 N.m (44 lb in).
3. Install the refrigerant pressure sensor wire harness connector.
4. Leak test the fittings using the J 39400-A.