Service Port HVAC: Service and Repair
Service Ports Replacement
Tools Required
* J39400-A Halogen Leak Detector
* J46246 Valve Core Removal Tool
Removal Procedure
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Use J46246 or equivalent to remove the valve core.
Installation Procedure
1. Use J46246 or equivalent to install and tighten the valve core.
2. Evacuate and charge the A/C system. Refer to Refrigerant Recovery and Recharging.
Important: To prevent loss of refrigerant charge, tighten the cap. Replace the cap if the seal is missing or damaged.
3. Test the affected A/C fittings for leaks using J39400-A.