P0A4B
DTC P0A4B
DTC Descriptors
DTC P0A4B
- Starter/Generator Position Sensor Circuit
Diagnostic Fault Information
Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. Initial Inspection and Diagnostic Overview
Circuit/System Description
The motor generator unit (MGU) position sensor is used for determining motor control of the MGU. The motor control consists of the angular position and speed of the MGU. The rotor is bolted on the MGU shaft, the stator is bolted on the MGU bracket and the sensor circuit is soldered on the motor control board in the starter/generator control module (SGCM). The SGCM monitors the position sensor circuit to detect a converter error (loss of speed signal or tracking).
Conditions for Running the DTC
The engine is running.
Conditions for Setting the DTC
R/D converter error (loss of signal or tracking) for 100 ms.
Action Taken When the DTC Sets
Stop PWM (MGU shutdown).
Conditions for Clearing the DTC
Clears 30 seconds after cycle wake up signal.
Diagnostic Aids
* Possible sensor cable short to ground, short to voltage or open.
* Possible MGU or SGCM fault.
* Possible wiring harness fault.
Circuit/System Testing
Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
1. Disconnect starter/generator control module (SGCM) connector C2.
2. Test the circuits in the SGCM to MGU Specification Table from the C2 connector to ground.
• If all of the circuits are within the minimum or maximum values specified, replace the SGCM.
3. Disconnect the MGU 10-pin connector.
4. Test the circuits in the SGCM to MGU Terminal Reference Table for an open, short to ground or high resistance.
• If all circuits test normal, replace the MGU.
Repair Instructions
Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests
Generator with Starter Replacement for MGU replacement..
Control Module References for SGCM replacement, setup, and programming.