DTC P1A0E or P1A0F
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. Initial Inspection and Diagnostic Overview
* Review Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions provides an overview of each diagnostic category.
DTC Descriptors
DTC P1A0E
- Battery Energy Control Module Hybrid Battery Voltage Sensor Circuit Low Voltage
DTC P1A0F
- Battery Energy Control Module Hybrid Battery Voltage Sensor Circuit High Voltage
Circuit/System Description
The battery energy control module (BECM) monitors the link voltage for a low and high voltage condition.
Conditions for Running the DTC
The engine is running.
Conditions for Setting the DTC
P1A0E
Pack Voltage raw A/D less than 0.5 volt.
P1A0F
Pack Voltage raw A/D greater than 4.5 volt.
Action Taken When the DTC Sets
P1A0E, P1A0F
Hybrid system is inactive.
Conditions for Clearing the DTC
P1A0E, P1A0F
Link voltage returns to normal.
Circuit/System Testing
Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
Caution: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
P1A0E
1. Remove the generator battery disconnect control module cover.
2. Measure and record the voltage at ring terminal 3 to ground.
3. Depress and hold the service disconnect switch and measure the voltage at ring terminal 1 to ground. The voltage should read the same as in step 2.
• If no voltage was measured at ring terminal 1 with service disconnect switch depressed, replace BECM.
4. Disconnect connectors C1 and C2 from the BECM.
5. Test for less than 6.5 volts between C1 terminal 1 and C2 terminal 1, while depressing the service disconnect switch.
• If greater than the specified range, replace BECM.
6. Remove the generator battery cover.
7. Measure the resistance between C2 terminal 1 and ring terminal 1. Should measure 700 - 800 ohms.
• If not within specified range, replace the harness assembly.
8. Measure the resistance between C1 terminal 1 and ring terminal 7. Should measure 700 - 800 ohms.
• If not within specified range, replace the harness assembly.
P1A0F
1. Remove the generator battery disconnect control module cover.
2. Measure and record the voltage at ring terminal 3 to ground. Should read pack voltage.
3. Measure the voltage at ring terminal 1 to ground. Should read no voltage.
• If greater than the specified range, replace the BECM.
4. Disconnect connectors C1 and C2 from the BECM.
5. Remove the generator battery cover.
6. Measure the resistance between C2 terminal 1 and ring terminal 1. Should measure 700 - 800 ohms.
• If not within specified range, replace the harness assembly.
7. Measure the resistance between C1 terminal 1 and ring terminal 7. Should measure 700 - 800 ohms.
• If not within specified range, replace the harness assembly.
Repair Instructions
Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests
Control Module References for BECM replacement, setup, and programming.