Operation CHARM: Car repair manuals for everyone.

Clock Malfunction



Clock Malfunction

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. Initial Inspection and Diagnostic Overview
* Review Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information






Circuit/System Description

The instrument panel is equipped with an analog clock. The analog clock utilizes the clock B+ circuit and the clock ground circuit to operate.

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the clock.
2. Ignition OFF, test for less than 1 ohm between the ground circuit terminal 2 and ground.

If greater than the specified value, test the ground circuit for an open/high resistance.

3. Verify that a test lamp illuminates between the B+ circuit terminal 1 and the ground circuit terminal 2.

If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.

4. If all circuits test normal, text or replace the clock.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests

Clock Replacement (Enclave)