Operation CHARM: Car repair manuals for everyone.
Do you have access to Mitchell1 Prodemand, or eautorepair.net DIY? If you are willing to share user/password (we can pay), please get in contact with us ASAP (truly, it is urgent): email operation-charm [[at]] tuta.io or click to submit anonymously

Parasitic Draw

TYPICAL PARASITIC LOADS

Typical parasitic load for this vehicle is 10-15 mA. If the vehicle does not have one of the following components, then subtract the parasitic load of the component for typical parasitic load of the vehicle (10-15 mA) to determine the parasitic load range for the vehicle being tested.

Note: During CD changer initialization, parasitic current draw will fluctuate between 3 mA to 1 A. The initialization period lasts up to a maximum of 90 seconds. After initialization, the CD changer parasitic current draw will stabilize at approximately 3 mA.

If the CD changer door is open and the light is illuminated, the parasitic current draw will be approximately 65 mA. The light will remain ON for 2 minutes. After the light goes out, the CD changer parasitic current draw will stabilize at approximately 3 mA.