Scan Tool Testing and Procedures
SEAT BELT: SEAT BELT WARNING SYSTEM: DATA LIST / ACTIVE TEST
DATA LIST / ACTIVE TEST
1. READ DATA LIST
HINT: Using an intelligent tester or Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
(a) Turn the ignition switch to OFF.
(b) Connect an intelligent tester or Techstream to the DLC3.
(c) Turn the ignition switch to ON.
(d) Turn the tester on.
(e) Enter the following menu items:
(1) Intelligent tester - Select: DIAGNOSIS / OBD/MOBD / BODY SYSTEM / (desired system) / DATA LIST /
(2) Techstream - Select: Body Electrical / (desired system) / Data List /
(f) According to the display on tester, read the "DATA LIST" or "Data List".
(1) Intelligent tester
METER:
SRS AIRBAG:
OCCUPANT DETECT:
(2) Techstream
Combination Meter:
SRS Airbag:
Occupant Detection:
2. PERFORM ACTIVE TEST
HINT: Using an intelligent tester or Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
(a) Turn the ignition switch to OFF.
(b) Connect an intelligent tester or Techstream to the DLC3.
(c) Turn the ignition switch to ON.
(d) Turn the tester on.
(e) Enter the following menus:
(1) Intelligent tester - Select: DIAGNOSIS / OBD/MOBD / BODY SYSTEM / METER / ACTIVE TEST /
(2) Techstream - Select: Body Electrical / Combination Meter / Active Test /
(f) According to the display on tester, perform the "ACTIVE TEST" or "Active Test".
(1) Intelligent tester
METER:
(2) Techstream
Combination Meter: