Operation CHARM: Car repair manuals for everyone.

With Select Monitor

CONNECT SELECT MONITOR

Select Monitor A/T Cartridge:





1. Install cartridge No. 498349300 and connect Select Monitor to data link connector beneath driver side instrument panel.

Select Monitor ON/OFF Switch:





2. Turn ignition and Select Monitor switches ON.
3. After display is shown, press slash "/" key.
4. After A/T mode is displayed, press function "[0]."

NOTE: Display returns to A/T mode when slash "/" is pressed during on-board diagnostic operation.

READ TROUBLE CODES

Select Monitor Key Pad And Code Display:





1. Connect Select Monitor.
2. Designate mode using function key. Press [F] [B] [0] [ENT] in that order.
3. Ensure trouble code(s) is shown.

PREVIOUS TROUBLE CODE READING

1. Connect Select Monitor.
2. Designate mode using function key. Press [F] [B] [1] [ENT] in that order.
3. Ensure trouble code(s) is shown.