Air Bleeding Control With Select Monitor

AIR BLEEDING CONTROL WITH SELECT MONITOR
1) Connect select monitor to data link connector beside driver's seat instrument panel lower.





(1) Data link connector (for Subaru select monitor and OBD-II general scan tool)
(2) Data link connector (for Subaru select monitor)

NOTE: When using data link connector (1) above, use ST. ST 498357200 ADAPTER CABLE

2) Start the engine.
3) Change select monitor to TCS mode by pressing the function key.





4) Press FD3 ENT key.





5) When the message shown in the figure is displayed, press ENT key.





6) Air bleeding control operation starts.





7) Select monitor indicates that air bleeding control is now operating.





8) When air bleeding control cannot be started (by system malfunction, etc.), the message shown in the figure will be displayed.

NOTE: Read the trouble codes. Repair faulty parts.