Pressure Control Solenoid Valve
Pressure Control Solenoid ValveREMOVAL
1. Disconnect the ground terminal from battery.
2. Remove the canister.
3. Disconnect the evaporation hoses (A) from joint pipes.
4. Remove the bolt which installs pressure control solenoid valve holding bracket on body.
5. Disconnect the connector from pressure control solenoid valve.
6. Disconnect the two evaporation hoses from pressure control solenoid valve.
7. Remove the pressure control solenoid valve with bracket.
8. Remove the pressure control solenoid valve from bracket.
9. Disconnect the vacuum hose from pressure control solenoid valve.
INSTALLATION
Install in the reverse order of removal.