Refrigerant Pressure Sensor / Switch: Service and Repair
Refrigerant Pressure Sensor: Removal and Installation
Removal
1) Discharge the refrigerant. Refer to [HFC-134a (R-134a) Service Procedure] Service and Repair.
2) Disconnect the refrigerant pressure sensor harness connector.
3) Remove the refrigerant pressure sensor from the condenser.
CAUTION:
Be careful not to damage the condenser fins.
Installation
Installation is in the reverse order of removal.
Refer to [Refrigeration System: Component] Component.
CAUTION:
- Be careful not to damage the condenser fins.
- Replace the O-ring of the refrigerant pressure sensor with a new one, then apply compressor oil to it for installation.
- After charging refrigerant, check for leaks.