Operation CHARM: Car repair manuals for everyone.

Starting and Charging: Service Precautions

CODED AUDIO ANTI-THEFT SYSTEM

Some models may be equipped with an audio coded anti-theft system that will disable the radio when the battery cable is disconnected. The system can be identified by the words ANTI-THEFT SYSTEM on the cassette tape lid. Obtain three digit customer code for input. Reset system after service as follows:
1. Obtain three digit audio anti-theft code.
2. Depress 1 (PRIG) while depressing righthand side of TUNE SEEK button, - - - will appear in tape operation display.
3. To enter first digit, depress 1 (PRIG) button repeatedly until the number of times depressed equals the first digit beginning with zero (depress the 1 button six times if the first digit is five).
4. To enter second digit, depress 2 (APS) button repeatedly until the number of times depressed equals the second digit beginning with zero.
5. To enter third digit, depress 3 (RPT) button repeatedly until the number of times depressed equals the third digit beginning with zero.
6. If - - - is displayed during code input, repeat procedure.
7. When code appears in display, depress and hold SCAN button until SEC appears.
8. When SEC disappears audio system should be operative.
9. If Err is displayed, repeat procedure. Attempting to input code more than nine times may permanently disable audio system.

RADIO PRESETS INFORMATION

1. When the negative ( - ) terminal cable is disconnected from the battery, memory of the clock and audio systems will be cancelled. So before starting work, make a record of the contents memorized by the audio memory system and audio protection system. When work is finished, reset the audio systems as before and adjust the clock.

R-12 AIR CONDITIONING SYSTEMS

The refrigerant used in car air conditioners is also known as R-12. It is colorless and odorless both as a gas and a liquid. Since it boils (vaporizes) at -21.7°F, it will usually be in a vapor state when being handled in a repair shop. But if a portion of the liquid coolant should come in contact with the hands or face, note that its temperature momentarily will be at least 22° below zero.

Protective goggles should be worn when opening any refrigerant lines. If liquid coolant does touch the eyes, bathe the eyes quickly in cold water. Then apply a bland disinfectant oil to the eyes. See an eye doctor.

When checking a system for leaks with a torch type leak detector, do not breathe the vapors coming from the flame. Do not discharge refrigerant in the area of a live flame. A poisonous phosgene gas is produced when R-12 is burned. While the small amount of this gas produced by a leak detector is not harmful unless inhaled directly at the flame, the quantity of refrigerant released into the air when a system is purged can be extremely dangerous if allowed to come in contact with an open flame.

Never allow the temperature of refrigerant drums to exceed 125°F. The resultant increase in temperature will cause a corresponding increase in pressure which may cause the safety plug to release or the drum to burst.

If it is necessary to heat a drum of refrigerant when charging a system, the drum should be placed in water that is no hotter than 125°F. Never use a blowtorch, or other open flame. If possible, a pressure release mechanism should be attached before the drum is heated.

Air conditioning systems are extremely sensitive to moisture and dirt. The importance of clean working conditions is extremely important, as the smallest particle of foreign matter in an air conditioning system will contaminate the refrigerant, causing rust, ice or damage to the compressor. For this reason, all replacement parts are sold in vacuum sealed containers and should not be opened until they are to be installed in the system. If, for any reason, a part has been removed from its container for any length of time, the part must be completely flushed using only R-12 to remove any dust or moisture that may have accumulated during storage. In cases of collision repairs where the system has been open for any length of time, the entire system must be purged completely and a new receiver-dehydrator must be installed because the element of the existing unit will have become saturated and unable to remove any moisture from the system once the system is recharged.

When making gauge connections, purge the gauge lines first by cracking the charging valve and allowing a small amount of refrigerant to flow through the lines, then connect the lines immediately.

Cleanliness is especially important when servicing compressors because of the very close tolerances used in these units. Consequently, repairs to the compressor itself should not be attempted unless all proper tools are at hand and a virtually spotless work area is provided.

R-134a AIR CONDITIONING SYSTEMS

R-134a is a non-toxic, non-flammable, clear odorless liquefied gas.
R-134a refrigerant is not compatible with R-12 refrigerant. Even small amounts of R-12 in a R-134a system can cause lubricant contamination, improper A/C performance or compressor failure. Never add R-12 to an R-134a system.

New service ports have been added to the compressor to prevent charging the system with R-12 refrigerant. R-134a systems require a special compressor lubricant. Use ND8 PAG compressor oil part No. 82300102 or equivalent when servicing system.

Avoid breathing A/C R-134a refrigerant and lubricant vapor or mist. Exposure may irritate eyes, nose and throat. Use only approved service equipment to discharge R-134a systems.

Air conditioning systems are extremely sensitive to moisture and dirt. The importance of clean working conditions is extremely important, as the smallest particle of foreign matter in an air conditioning system will contaminate the refrigerant, causing rust, ice or damage to the compressor. For this reason, all replacement parts are sold in vacuum sealed containers and should not be opened until they are to be installed in the system. If, for any reason, a part has been removed from its container for any length of time, the part must be completely flushed using only R-134a to remove any dust or moisture that may have accumulated during storage. In cases of collision repairs where the system has been open for any length of time, the entire system must be purged completely and a new receiver-dehydrator must be installed because the element of the existing unit will have become saturated and unable to remove any moisture from the system once the system is recharged.

When making gauge connections, purge the gauge lines first by cracking the charging valve and allowing a small amount of refrigerant to flow through the lines, then connect the lines immediately.

Cleanliness is especially important when servicing compressors because of the very close tolerances used in these units. Consequently, repairs to the compressor itself should not be attempted unless all proper tools are at hand and a virtually spotless work area is provided.

BRAKE FLUID WARNING

Do not reuse any old brake fluid, as it has contaminants and contains water which lowers the boiling point of the fluid. Be careful not to spill any brake fluid on any painted surfaces. If any brake fluid is spilled onto painted surfaces, immediately flood the area with lots of water.

FUEL PRESSURE RELEASE

Before working on the fuel system, disconnect the negative (-) terminal cable from the battery.
1. When disconnecting the high pressure fuel line, a large amount of gasoline may come out so observe these procedures:
a. Put a container under the connection.
b. Slowly loosen the connection.
c. Disconnect the connection.
d. Plug the connection with a rubber plug.