O/D Main Switch & O/D Off Indicator Light Circuit
O/D Main Switch & O/D Off Indicator Light Circuit
CIRCUIT DESCRIPTION
The O/D main switch contacts go off when the switch is pushed in and come on when it is pushed once again.
In O/D main switch OFF position, the O/D OFF indicator lights up, and the ECM prohibits shifting to overdrive.
WIRING DIAGRAM
INSPECTION PROCEDURE
O/D OFF indicator light does not light up
O/D OFF indicator light remains ON