Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Air Flow Meter/Sensor: Testing and Inspection

Fig. 4 Air flow meter connector terminals:




Fig. 24 Resistance specifications:





1. Disconnect air flow meter electrical connector and measure resistance between connector terminals, Fig. 4.
2. Readings obtained should correspond to resistance values shown in chart, Fig. 5.
3. With air flow meter removed from vehicle, check resistance at electrical connector, Fig. 4. With measuring plate fully closed, resistance between terminals E(2) and VS should be 20-100 ohms. In any other position reading should be 20-1000 ohms.