Extension Housing
EXTENSION HOUSINGExtension Housing Inspection
1. INSPECT EXTENSION HOUSING BUSHING
Using a cylinder gauge, measure the inside diameter of the extension housing bushing.
Maximum inside diameter: 38.09 mm (1.4996 inch)
If the inside diameter is greater than the maximum, replace the extension housing.