EGR Backpressure Transducer: Testing and Inspection
EGR VACUUM MODULATOR INSPECTION
1. DISCONNECT VACUUM HOSES FROM EGR VACUUM MODULATOR.
- Disconnect these vacuum hoses:
- Vacuum hose from P port
- Vacuum hose from Q port
- Vacuum hose from R port
2. INSPECT EGR VACUUM MODULATOR OPERATION.
- Block ports P and R with your finger.
- Blow air into port Q.
- Check that the air passes through to the air filter side freely
- Start the engine, and maintain speed at 3,500 rpm.
- Repeat the above test.
- Check that there is a strong resistance to air flow.
3. RECONNECT VACUUM HOSES TO EGR VACUUM MODULATOR.