Operation CHARM: Car repair manuals for everyone.

Service Hints

POWER RELAY
4-2: Closed with the Ignition SW at ON position or Key OFF operated

M 3 MOON ROOF CONTROL RELAY
11-Ground: Always continuity
6-Ground: Approx. 12 Volts with the Ignition SW at ON position or key OFF operated
4-Ground: Approx. 12 Volts with the Ignition SW ON and the Moor Roof control SW at Close or Up position
(Except Approx. 100 mm (3.941 in.) 2 Seconds in the before Closed position)
5-Ground: Approx. 12 Volts with the Ignition SW ON and the Moon Roof control SW at Open or Down position
9-Ground: Approx. 12 Volts --> 0 Volts with from open to close
0 Volts with Up or Down position
0 Volts --> Approx. 12 Volts with Approx. 100 mm (3.941 in.) 2 Seconds in the before Closed position
8-Ground: 0 Volts --> Approx. 12 Volts with from Up to Down position

M 4 MOON ROOF CONTROL SW
5-4: Closed with the Moon Roof control SW at Up position
6-4: Closed with the Moon Roof control SW at Close position
2-4: Closed with the Moon Roof control SW at Down position
3-4: Closed with the Moon Roof control SW at Open position
4-Ground: Always continuity