Manifold Gauge Installation/Removal

MANIFOLD GAUGE SET INSTALLATION
1. CONNECT CHARGING HOSES TO MANIFOLD GAUGE SET

Tighten the nuts by hand.


CAUTION: Do not connect the wrong hoses.





2. CONNECT QUICK DISCONNECT ADAPTERS TO CHARGING HOSES
Tighten the nuts by hand.

3. CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE SET

4. REMOVE CAPS FROM SERVICE VALVES ON REFRIGERANT LINE




5. CONNECT QUICK DISCONNECT ADAPTERS TO SERVICE VALVES



HINT: Push the quick disconnect adapter onto the service valve. then slide the sleeve of the quick disconnect adapter downward to lock it.


MANIFOLD GAUGE SET REMOVAL
1. CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE SET





2. DISCONNECT QUICK DISCONNECT ADAPTERS FROM SERVICE VALVES ON REFRIGERANT LINE


HINT: Slide the sleeve of the quick disconnect adapter upward to unlock the adapter and remove it from the service valve.


3. INSTALL CAPS TO SERVICE VALVES ON REFRIGERANT LINE