Service Hints
C18 CRUISE CONTROL ACTUATOR WITH ECU6-GROUND: Approx. 12 Volts with brake pedal depressed
4-GROUND: Approx. 12 Volts with ignition SW at ON position
10-GROUND: Always continuity
9-GROUND: Always continuity
C14 CRUISE CONTROL SW [COMB. SW]
5-3: Closed with CRUISE SW ON
4-3: Approx. 68 Ohms with RESUME/ACCEL SW ON
Approx. 198 Ohms with SET/COAST SW ON
Approx. 418 Ohms with CANCEL SW ON