Operation CHARM: Car repair manuals for everyone.

Power Window

B16 (A) BODY ECU
3-GROUND: Always approx. 12 Volts
10 -GROUND: Approx. 12 Volts with ignition SW at ON position
(A) 19-GROUND: Continuity with front LH door opened

PWR RELAY [DRIVER SIDE J/B]
5-3: Closed with ignition SW ON and stays at 12 Voltsfor 43 seconds after the ignition SW is turned OFF, but if a door is opened in this 43 seconds period, voltage will drop to 0 Volts

D16 DOOR COURTESY SW FRONT LH
1-GROUND: Continuity with door opened

P 4 POWER WINDOW CONTROL SW FRONT RH
7-GROUND: Always approx. 12 Volts
12-GROUND: Always continuity

P 5, P 6 POWER WINDOW CONTROL SW REAR LH, RH
4-GROUND: Approx. 12 Volts with ignition SW ON and stays at 12 Volts for 43 seconds after the ignition SW is turned OFF, but if a door is opened in this 43 seconds period, voltage will drop to 0 Volts

P 7 (A) POWER WINDOW MASTER SW
A 4-GROUND: Always continuity
A 10 -GROUND: Approx. 12 Volts with ignition SW ON and stays at 12 Volts for 43 seconds after the ignition SW is turned OFF, but if a door is opened in this 43 seconds period, voltage will drop to 0 Volts
A 3-GROUND: Always approx. 12 Volts

WINDOW LOCK SW
Open with window lock SW at LOCK position