INTEGRATION RELAY1-GROUND : Always approx. 12 Volts
4-GROUND : Continuity with the one of each door (front RH, Rear LH and RH) open
6-GROUND : Continuity with the Front LH door open
10-GROUND : Always continuity
D12, D13, D14, D15 DOOR COURTESY SW FRONT LH, RH, REAR LH, RH
1-GROUND : Closed with the door open
L 8 LUGGAGE COMPARTMENT LIGHT SW