S6 STOP LIGHT SW2-1 : Closed with the brake pedal depressed
L2 LIGHT FAILURE SENSOR
1, 2, 7-Ground : Approx. 12 Volts with the stop light SW ON
4, 8-Ground : Approx 12 Volts with the ignition SW at ON position
11-Ground : Always continuity