Operation CHARM: Car repair manuals for everyone.

Compressor Speed Sensor: Testing and Inspection




INSPECT COMPRESSOR LOCK SENSOR RESISTANCE
a. Disconnect the connector.
b. Measure resistance between terminals 1 and 2.
Standard resistance: 570 - 1,050 Ohms at 20° C (68 ° F)
If resistance is not as specified, replace the compressor.