Service Hints
D15, D16 DOOR COURTESY SW LH, RH1-GROUND : Continuity with Door open
I15-A, I19-B INTEGRATION RELAY
6-GROUND : Approx. 12 Volts with Ignition SW at ON position
(B) 11-GROUND : Always Continuity
(A) 5-GROUND : Continuity with LH Door opened
(A) 9-GROUND : Continuity with RH Door opened
P 6 POWER WINDOW CONTROL SW RH
4-GROUND : Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 45 Seconds after the Ignition SW is turned OFF, but if a Door is opened in this 45 Second period, Voltage will drop to 0 Volts
P 7 POWER WINDOW MASTER SW
6-GROUND : Always Continuity
9-GROUND : Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 45 Seconds after the Ignition SW is turned OFF, but if a Door is opened in this 45 Seconds period, Voltage will drop to 0 Volts
3-GROUND : Approx. 12 Volts with Ignition SW at ON position and master SW at UP position
4-GROUND : Approx. 12 Volts with Ignition SW at ON position and master SW at DOWN or AUTO DOWN position
WINDOW LOCK SW
Open with Window Lock SW at LOCK position