Service Hints
D 15, D 16 DOOR COURTESY SW LH, RH1-GROUND : Continuity with door open
I 15-A, I 19-B INTEGRATION RELAY
6-GROUND : Approx. 12 volts with ignition SW at ON position
A 11-GROUND : Always approx. 12 volts
A 5-GROUND : Continuity with LH door opened
A 9-GROUND : Continuity with RH door opened
P 6 POWER WINDOW CONTROL SW RH
4-GROUND : Approx. 12 volts with ignition SW ON and stays at 12 volts for 45 seconds after the ignition SW is turned OFF, but if a door is open in the 45 seconds period, voltage will drop to 0 volts
P 7 POWER WINDOW MASTER SW
6-GROUND : Always continuity
9-GROUND : Approx. 12 volts with ignition SW ON and stays at 12 volts for 45 seconds after the ignition SW is turned OFF, but if a door is opened in this 45 seconds period, voltage will drop to 0 volts
3-GROUND : Approx. 12 volts with ignition SW at ON position and master SW at UP position
4-GROUND : Approx. 12 volts with ignition SW at ON position and master SW at DOWN or AUTO DOWN position
WINDOW LOCK SW
Open with window lock SW at LOCK position